    Sight glass level ok cold... high when hot. Why?

    Gene Cafe Coffee Roaster $850 - Free Beans Free Freight
    Can anyone tell me what could cause a "normal" water level reading in a sight glass on a cold machine to increase above the max level and up over the top of the sight glass so that I can no longer see the meniscus under operating temperature....and then drop back to normal when cold again? It's driving me crazy.


    Thanks,
    Paolo

  2. #2
    Site Sponsor coffee_machinist's Avatar
    Join Date
    Jun 2011
    Posts
    683
    most likely there's a blockage at one end that's only present when the parts have expanded from heat. This has happened with one of my Europiccoli, and it was the top flat surface of the glass butting up against the teflon seal that is under the sight glass plug, effectively blocking it from one end.

  3. #3
    Senior Member
    Join Date
    Sep 2005
    Posts
    502
    Hi CM,
    Thanks for replying.

    Does that mean that to get the sight glass to operate properly, I would have to dismantle and re-set the sight glass? Or is this something that might actually get better with use. I say this because (on this new machine) everything actually worked properly through one cold-hot-cold cycle properly yesterday...but played up several times today.

  4. #4
    Site Sponsor coffee_machinist's Avatar
    Join Date
    Jun 2011
    Posts
    683
    What sort of machine is it? You *might* be able to wiggle the glass gently up or down by twisting when it's cold, but for peace of mind I'd be pulling it all apart and checking the seals. I'm guessing the machine doesn't auto-fill, so you really want to know where the water level is with confidence.

  5. #5
    Senior Member
    Join Date
    Sep 2005
    Posts
    502
    It does actually auto-fill...so I suppose as long as the water level is ok each time that I check it when cold, then all should be ok....still....a pain in the nether bits.

    Why would it have worked properly (once) yesterday?

  6. #6
    Member
    Join Date
    Aug 2006
    Posts
    62
    a Londinium 1 ?

  7. #7
    Senior Member
    Join Date
    Sep 2005
    Posts
    502
    No...it's not a Londinium 1...

    The level in the sight glass has dropped on 2 separate occasions to the proper point when I operated the steam wand to froth milk. It will remain at the proper level until shutdown but start to rise again once the anti-vac valve shuts (and pressure in the boiler starts to build) on the next turn-on.

    I drained a couple of cups out of the hot water tap and the level dropped then accordingly too....and stayed there until heating up the next day.

    It is still driving me crazy!



Similar Threads

  1. In a glass of their own...
    By scoota_gal in forum General Coffee Related...
    Replies: 148
    Last Post: 13th November 2018, 12:57 PM
  2. Rancillio L6 cannot see water level in sight glass
    By rider in forum Brewing Equipment - Extreme Machines ($3000+)
    Replies: 5
    Last Post: 30th August 2012, 08:13 PM
  3. pavoni Sight Glass cover removal
    By stargirl in forum General Coffee Related...
    Replies: 0
    Last Post: 7th March 2012, 01:39 PM
  4. Sight or Sound??
    By crafty_butcher in forum Home Roasting - Tips, Tricks, Ideas
    Replies: 2
    Last Post: 18th September 2007, 05:29 PM

Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
  •