    Running less elements

    Gene Cafe Coffee Roaster $850 - Free Beans Free Freight
    Hi guys

    I'm new to the whole pro coffee machine setup.

    I've got a leone bv 2 group machine and want to run one less element to be able to use a 10 amp socket safely.
    Issue is I have no idea what to look for.
    Does anyone have any work instructions or images? I'm slightly proficient with electrical stuff but don't want to disconnect something I shouldn't be haha

    Thanks

    John

  2. #2

  3. #3
    Senior Member sprezzatura's Avatar
    Join Date
    Dec 2013
    Location
    Hervey Bay, QLD
    Posts
    930
    Yes (normal caveats apply).

    This is my personal project: I ran up a 4 group single-phase, 25amp CMA with a 6kW element that was jumped (3 poles phase; 3 poles common).

    Remove jumpers. Determine continuity from one pole to another. Attach phase and common (these are sloppy but I only need to run this monster up three times to full steam - 1.2 bar in this case to test).

    I made up a standard 10amp plug that came off a dead domestic machine and, as depicted, attached to a terminal block.

    Stand clear of conducting material and turn on.

    So ... the 6kW 6 pole element hobbled to 2 poles like so soaked 9.85amps/2.4kW @ 240VAC (about 24.5 Ohms).

    Perfectly fine to test (test only).

    For your safety, and possibly my ass, Do not attempt this without a RESIDENTIAL RCD OR PORTABLE RCD.

    Please PM me for details or the forum will (burn me) chip in with other pointers.

  4. #4
    Senior Member sprezzatura's Avatar
    Join Date
    Dec 2013
    Location
    Hervey Bay, QLD
    Posts
    930
    Oh ... post images of your BV's internal pstat/element set up for us to look please!

  5. #5
    Mal Dimal's Avatar
    Join Date
    Oct 2004
    Location
    Warwick, QLD
    Posts
    16,869
    Personally, I believe that if you need to ask these sorts of questions, you should be employing the services of a licensed and qualified person to do the work for you.

    Very rarely get second chances with 240V AC...

    Mal.
    GreenBeanGenii, TC and sprezzatura like this.

  6. #6
    Senior Member sprezzatura's Avatar
    Join Date
    Dec 2013
    Location
    Hervey Bay, QLD
    Posts
    930
    ... and Mal is perfectly correct. But if you're unable to find someone to do this who's qualified, it is possible. If you are located anywhere near a sponsor or a service centre I highly recommend you take the machine in as there may be other issues to address.

  7. #7
    BFY
    BFY is offline
    Member
    Join Date
    Nov 2015
    Posts
    45
    Oh god I feel stupid. I've attached the pic found the element I wasn't even looking at it haha
    All good now

  8. #8
    Senior Member noidle22's Avatar
    Join Date
    Mar 2012
    Location
    Bathurst
    Posts
    1,144
    Quote Originally Posted by BeansForYou View Post
    Oh god I feel stupid. I've attached the pic found the element I wasn't even looking at it haha
    All good now
    I assume you mean you figured it out, but if not:

    1. Remove two lower spade terminals.
    2. Secure safely away from the boiler, chassis or terminals
    3. Done
    sprezzatura and BFY like this.

  9. #9
    BFY
    BFY is offline
    Member
    Join Date
    Nov 2015
    Posts
    45
    Yep capped them off. Out of time to try it out tonight. Will run down to bunnings to make a 15 - 10 amp adapter. Machine needs a good clean and might be able to pull a coffee tomorrow
    sprezzatura likes this.

  10. #10
    Senior Member noidle22's Avatar
    Join Date
    Mar 2012
    Location
    Bathurst
    Posts
    1,144
    15A to 10A adapter you say?



    But seriously don't do that.........
    sprezzatura likes this.

  11. #11
    BFY
    BFY is offline
    Member
    Join Date
    Nov 2015
    Posts
    45
    Will be making sure it doesn't draw more than the 10 amps.
    It's only for cleaning not for regular usage.
    It'll be plugged into a gpo running on its own 16 amp rcb in the garage

  12. #12
    Senior Member sprezzatura's Avatar
    Join Date
    Dec 2013
    Location
    Hervey Bay, QLD
    Posts
    930
    I had a laugh! I've see it done - right in front of my eyes. Couldn't believe it.

  13. #13
    Mal Dimal's Avatar
    Join Date
    Oct 2004
    Location
    Warwick, QLD
    Posts
    16,869
    I've also witnessed the resultant damage caused when the "handyman" forgot about his modification (on a welder), and nearly burnt his garage down. Many years ago but I'm sure this sort of "accident" still happens today....

    Don't let your Insurance Company discover what you have done if the need for a claim ever eventuates. They have ways of discovering these sorts of things though...

    Mal.
    sprezzatura likes this.

  14. #14
    BFY
    BFY is offline
    Member
    Join Date
    Nov 2015
    Posts
    45
    hey guys i am still alive! haha, i reduced the element, which brought the machine down to 7.5amp. I only wanted to make sure it turns on and my mate finished a job early yesterday so he came out and fitted off a new 15amp socket in the garage for me (yes he is certified)

    thanks for the help guys
    Dimal and sprezzatura like this.