    ACS Vesuvius - Power Requirement

    Gene Cafe Coffee Roaster $850 - Free Beans Free Freight
    Hi Fellow CSers,

    Does the ACS Vesuvius require a 15 Amp GPO? I'm currently currently considering this as my next upgrade. Thanks.

    Jason.

  2. #2
    TC
    TC is offline
    .
    Join Date
    Oct 2004
    Location
    Melbourne
    Posts
    14,665
    It's 10A Jason

  3. #3
    Member
    Join Date
    Jan 2007
    Location
    Melbourne
    Posts
    32
    Quote Originally Posted by Talk_Coffee View Post
    It's 10A Jason
    Thanks Chris. That does make things a whole lot easier. I'm guessing not all 2300W is drawn at the same time? Calculate current draw for 2300W works out to be

    2300/(0.8 x 230) = 12.5 Amps.

  4. #4
    Mal Dimal's Avatar
    Join Date
    Oct 2004
    Location
    Warwick, QLD
    Posts
    16,870
    No need to use a PF of 0.8...
    90% of the load is resistive.

    Mal.

  5. #5
    Member
    Join Date
    Jan 2007
    Location
    Melbourne
    Posts
    32
    Quote Originally Posted by Dimal View Post
    No need to use a PF of 0.8...
    90% of the load is resistive.

    Mal.
    Thanks for pointing that out Mal.
    Assuming 100% resistive load, the power factor would be 1. Making the current draw at exactly 10 Amps. Would that be correct?
    Dimal likes this.

  6. #6
    TC
    TC is offline
    .
    Join Date
    Oct 2004
    Location
    Melbourne
    Posts
    14,665
    The machine is protected by a 10A fuse.

  7. #7
    Member
    Join Date
    Jan 2007
    Location
    Melbourne
    Posts
    32
    Quote Originally Posted by Talk_Coffee View Post
    The machine is protected by a 10A fuse.
    Thanks Chris. Thanks all I need.

  8. #8
    Mal Dimal's Avatar
    Join Date
    Oct 2004
    Location
    Warwick, QLD
    Posts
    16,870
    Quote Originally Posted by onewheel View Post
    Assuming 100% resistive load, the power factor would be 1. Making the current draw at exactly 10 Amps. Would that be correct?
    In a perfect world, yes...

    Mal.

  9. #9
    Senior Member
    Join Date
    Dec 2008
    Posts
    149
    Quote Originally Posted by onewheel View Post
    Thanks Chris. Thanks all I need.
    Keep in mind the Vesuvius remains in standby mode if you plan on using the built-in 7 day on/off timer. In which case it wouldn't hurt to add a little surge protection. I'm running one of these between my Vesuvius and the GPO (Thor C2 - Smart Filter Duo) - better than nothing I suppose...