    HX machine problems- Brugnetti

    Gene Cafe Coffee Roaster $850 - Free Beans Free Freight
    Hi al
    I`m feeling like a complete beginner. I have just purchased a used Brugnetti Simona top machine to replace my Sunbeam EM 6910. It has become apparent that its functionality is far different to the EM6910. I`ve adjust grind & tamp pressures but it all just coming out like crap. Slow pours and it tastes bitter I`ve ground fine and coarse but still no good. Can some explain cooling flush, i`m thinking maybe this is the issue, is this no knock the steam out of the pour before it starts? Any help & tips would be appreciated. Also about every 20min the pump start and runs for about 5sec is this just topping up the boiler.
    Rob

  2. #2
    Senior Member
    Join Date
    Oct 2012
    Posts
    182
    I would recommend reading "how I stopped worrying and learnt to love HXs" as a starting guide. Yes, you need to do a cooling flush. There are two methods: long flush, dose and go; or short flush and go immediately.

    The pump automatically refills the boiler in cases where water is removed i.e. after steaming, but if it is sitting idle I don't think it should need to. Also, as a guide what is the range of pressure in your boiler?

    Well thats all I know, someone who has mastered the art of HX might want to give their two cents.

  3. #3
    Member
    Join Date
    Feb 2009
    Posts
    84
    Read the article and I think it makes sense. The pressure in the boiler when idle cycles between 1.4-1.5. As for the pump coming on when idle it has not done that today. I did only get the machine yesterday so hard to say if it happens all the time.

  4. #4
    Senior Member
    Join Date
    Oct 2012
    Posts
    182
    If you haven't already it might also help to do a chemical backflush. I've found with some old machines when users don't backflush with detergent (i.e. cafetto) the shots suffer. 1.4-1.5 sounds high but this depends on the machine. Perhaps the Brungetti has a short path through the HX and compensates with a higher temp boiler?

  5. #5
    Senior Member chokkidog's Avatar
    Join Date
    Apr 2008
    Location
    Victoria, Australia
    Posts
    2,095
    It appears that Brugnetti factory settings are way too high.

    Adjust the pressurestat down and try a couple of settings......... 1.0-1.1, 1.1- 1.2, 1.2-1.3

  6. #6
    Member
    Join Date
    Feb 2009
    Posts
    84
    Backflush is the next thing on my list. My Sunbeam had an automatic backflush cycle so how many times through would I do a backflush and for how long each time?

  7. #7
    Member
    Join Date
    Feb 2009
    Posts
    84
    Without sounding like a total noob does pressure relate to boiler temperature ? I did a cooling flush and checked the water temp and it levelled out at about 92 Deg I read that 95 deg is the desired brew temp?

  8. #8
    TOK
    TOK is offline
    Senior Member
    Join Date
    Apr 2013
    Posts
    697
    Yes boiler pressure does relate to boiler temperature, but there are other things that also relate to brew temperature...

    95 is invariably too high...I dunno where you read that. A fluctuation of say 88 to 92 would be considered to be within spec.

  9. #9
    Member
    Join Date
    Feb 2009
    Posts
    84
    Tok. I read that from the link that Buur had posted above Here is the extract.

    "In the case of most U.S. espresso lovers, their target brew temperature is around 201-203F; for some countries overseas, the tastes are for a cooler 192F."

  10. #10
    Senior Member chokkidog's Avatar
    Join Date
    Apr 2008
    Location
    Victoria, Australia
    Posts
    2,095
    Quote Originally Posted by RobertC View Post
    Without sounding like a total noob does pressure relate to boiler temperature ? I did a cooling flush and checked the water temp and it levelled out at about 92 Deg I read that 95 deg is the desired brew temp?
    Where and how did you measure 92C?

    Quote Originally Posted by TOK View Post
    Yes boiler pressure does relate to boiler temperature, but there are other things that also relate to brew temperature...

    95 is invariably too high...I dunno where you read that. A fluctuation of say 88 to 92 would be considered to be within spec.
    Agreed TOK, but I would squeeze it out to 90C- 93C so that the mid range is about 92 +/-. My opinion only;....... I've had some great coffee tasting pretty awful at 85C and start
    to get twitchy at anything sub 90C. ;-D

  11. #11
    Member
    Join Date
    Feb 2009
    Posts
    84
    Measured 92c with the probe up the portafilter spout.

  12. #12
    TOK
    TOK is offline
    Senior Member
    Join Date
    Apr 2013
    Posts
    697
    Quote Originally Posted by chokkidog View Post
    Agreed TOK, but I would squeeze it out to 90C- 93C so that the mid range is about 92 +/-. My opinion only;....... I've had some great coffee tasting pretty awful at 85C and start
    to get twitchy at anything sub 90C. ;-D
    Yes, 92 +/- is my "standard" and I also don't like to see it below 90 (and I use a *PID* BFC Junior Extra machine for cupping so easily managed), however a reasonable fluctuation for an HX machine would be between the figures I mentioned, where in reality you don't really know anyway unless you go to the trouble of using a thermocouple in the accepted way.

    95 degrees burns coffee no matter which country you are in except perhaps where the particular ethnic custom is to use hard / very dense beans such as robustas or some of the indonesians for example, however this is not really for newbies to worry about
    chokkidog likes this.

  13. #13
    Senior Member
    Join Date
    Oct 2012
    Posts
    182
    Ah, a quick google search shows that the settings leaving the factory can be quite high (up to 1.5-1.65 Barr!) which is intentional due to the short HX path, but the manual recommends 1.3-1.5.

  14. #14
    Member
    Join Date
    Sep 2010
    Posts
    55
    Quote Originally Posted by RobertC View Post
    Hi al
    Also about every 20min the pump start and runs for about 5sec is this just topping up the boiler.
    Rob
    Hi Rob. The pump was recently running fairly regularly to top up the boiler on my machine too - and getting more often. I noticed a noise like steam escaping that used to happen as the machine warmed up was now constant. It turned out that there is a valve in the middle of the boiler top that had some corrosion. When the boiler warms up it pops up and stops steam escaping. However, with the corrosion it wasn't sealing and steam was constantly escaping - causing water to condense in the machine and also causing the pump to start more often.

    Since I dismantled the valve and cleaned off the corrosion with wet and dry the pump no longer starts so often.

    Could be something to check.

    Cheers,
    Tristan

  15. #15
    Senior Member
    Join Date
    Oct 2011
    Posts
    1,376
    Sounds like you might be describing an anti-vacuum valve?

  16. #16
    Member
    Join Date
    Sep 2010
    Posts
    55
    Quote Originally Posted by MrJack View Post
    Sounds like you might be describing an anti-vacuum valve?
    Thank you MrJack. Now you say it, that is exactly what it would be.

  17. #17
    Senior Member artman's Avatar
    Join Date
    Jun 2006
    Posts
    2,409
    They usually have an o-ring for the seal. It can perish/go hard. You could replace the o-ring (bearing shop) or the entire valve from one of the sponsors. They are not expensive.

    Cheers

  18. #18
    Member
    Join Date
    Sep 2010
    Posts
    55
    Thanks Artman. My o-ring looked ok so I left it in place and my anti-vac valve is all good after my work with the wet and dry. I guess my point was that if the pump is running often then it could be an indication that water or steam is escaping the boiler. It may then be worth examining the machine to see if this is the case and where.