Results 1 to 4 of 4

Thread: isomac zaffiro boiler leaking small hole need advice

  1. #1
    Junior Member
    Join Date
    May 2013
    Location
    south australia
    Posts
    15

    Wink isomac zaffiro boiler leaking small hole need advice

    Gene Cafe Coffee Roaster $850 - Free Beans Free Freight
    Hi i had noticed that my machine was not pulling shots as it normally should. So i took a look inside and found its has a small hole on the weld at the top of the boiler. There was a snail trail running down the face and some calcium deposits on the hole. Does any know if it can be welded or do a need a new one. its a copper boiler nickle plated with chrome exterior.

    Thanks

  2. #2
    Mal Dimal's Avatar
    Join Date
    Oct 2004
    Location
    Warwick, QLD
    Posts
    16,443
    G'day br41...

    You should be able to find a plumber or refrigeration tech. who could fix that up for you.

    Could probably help out a bit by cleaning all around the area with a small wire brush first up, so as to reduce the time spent doing the actual repair. Probably only take a few minutes...

    Mal.

  3. #3
    Junior Member
    Join Date
    May 2013
    Location
    south australia
    Posts
    15
    ok Thanks Dimal. I have sealed it with epoxy resin so i will see it works. if resign fails ill take to a plumber. Next problem.

    The machine is only staying on for a few minutes then trips the circuit breaker. Any Ideas as to what is causing this. I had to remove the boiler to repair it and the only wires i disconnected where at the bottom of the boiler. i drawed a pic so i could put the wires back to there same positions. Thanks

  4. #4
    Mal Dimal's Avatar
    Join Date
    Oct 2004
    Location
    Warwick, QLD
    Posts
    16,443
    Behmor Brazen - $249 - Free Freight
    RCD tripping could be down to several things including water contamination of exposed conductors, allowing for current leakage to earth.
    Most likely though, probably due to a dodgy boiler element or Boiler Fill Solenoid Coil.
    If you are not au fait with 240V AC electrics and troubleshooting thereof, I would suggest dropping your machine into a reputable specialist repairer, such as any of our Site Sponsors.

    Mal.