    Expobar Office Control Pump Running

    Gene Cafe Coffee Roaster $850 - Free Beans Free Freight
    Today my office control started some odd behaviour.

    The boiler fill pump is running continuously and forcing hot water out of the steam wand (not quite steam). I opened up the steam valve to relieve the pressure and it 1/2 filled a 600ml milk pitcher. The pump stopped for a little bit but started again 20 - 30 secs later.

    This obviously isnt normal behaviour, but does it sound serious?

    Cheers

    Sen

  2. #2
    TC
    TC is offline
    .
    Join Date
    Oct 2004
    Location
    Melbourne
    Posts
    14,665

    Re: Expobar Office Control Pump Running

    Hi Senator, it needs to be looked at...

    It will be the autofill board and the element may be shot as well...

    Time to visit your locak bloke I am afraid.

    Hope its a quick repair :(

    Chris

  3. #3
    Senior Member
    Join Date
    Mar 2008
    Posts
    433

    Re: Expobar Office Control Pump Running

    that sounds expensive :(

    Ive turned it off for a while and back on again. its heated up ok, so guess the element is ok. pump came on briefly and then off again (as it does most mornings when switching it on cold) but as soon as pressure built up, it started pumping again.

    moved the machine, there was quite a bit of water underneath it.

    Did a google and came up with another thread on here which started out as a vac valve (?) but eneded up being control board replacement.


  4. #4
    Senior Member
    Join Date
    Mar 2008
    Posts
    433

    Re: Expobar Office Control Pump Running

    took out the power and opened up and had a look around inside. there didnt appear to be any leaks or anything inside. made sure that all the connectors were well seated but basically, didnt really do anything.

    turned it back on, heated up as normal, no continuous pump etc, made a normal shot, steamed a jug of milk, still nothing wrong or unusual.

    somthing loose maybe?

    It started this morning when I was making a single. Hadnt adjusted the grind and it choked the machine. It was then that the problem first started. Something stuck open / not closed properly that should have been is my best guess, but seems to be ok (for now). Will still have to keep an eye on it I guess

    Sen

  5. #5
    Mal Dimal's Avatar
    Join Date
    Oct 2004
    Location
    Warwick, QLD
    Posts
    17,120

    Re: Expobar Office Control Pump Running

    May even be a slightly scaled up Level Probe too Sen.... :-?

    With the power off and unplugged, remove your cover(s) again and see if you can withdraw the Probe to check it out, then clean if necessary. Make sure to note what depth its set at before removing though.... ;)

    Mal.



Similar Threads

  1. !!SOLD!!: Expobar Office Control
    By barnsey in forum SOLD
    Replies: 14
    Last Post: 3rd August 2011, 01:20 PM
  2. !!SOLD!!: Expobar Office Control (FA)
    By mattchewhart in forum SOLD
    Replies: 7
    Last Post: 2nd July 2010, 05:04 PM
  3. Expobar Office Control Semi vs Expobar Office Leva
    By bluedevilfish in forum Brewing Equipment (non-machine specific)
    Replies: 10
    Last Post: 14th December 2006, 11:58 PM

Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
  •