    Measuring Group Head Pressure on a HX machine

    Gene Cafe Coffee Roaster $850 - Free Beans Free Freight
    Hi All,

    I recently upgraded to the beasty Rancilio S24, which is just a joy to run.

    Quick question though, would anyone know how to measure the group head pressure (as opposed to the boiler pressure, which doesnt seem to move from the 1.3-1.5 bar mark while in use)? I was thinking of setting the OPV to 9 bar at the group, but don't have any fancy brew pressure PF to do so. Is there any other way to set it up like that??

    Cheers,
    Aaron

  2. #2
    Not a Shoe Jimmytheboot's Avatar
    Join Date
    Jan 2009
    Location
    Melbourne
    Posts
    246
    I can lend you a portafilter+gauge if you can pickup/dropoff in the city, but I dont have a valve to regulate the allowed flow, so you just loosen up the fittings until 60ml drips out over 30 seconds. Send me a PM

  3. #3
    Not a Shoe Jimmytheboot's Avatar
    Join Date
    Jan 2009
    Location
    Melbourne
    Posts
    246
    But without a gauge, take the return hose out of the tank (The hose with nothing on the end), and measure the outflow with a blind basket.

    The EP5 pump graph is below, 100% of the flow will be going through the return hose, so check how many ml/min comes out and find the range it falls in on the graph, dotted lines represent the tolerance/variation that is possible, so if you measured 260ml/min like in the graph, it could be anywhere between 7 and 10 bar. This does not take into account any pressure losses happening between the OPV and the group, for that you need a portafilter gauge with appropriate flow.



    And take it easy on the pump, the specs say it can run for 2 minutes on with 1 minute breaks.

  4. #4
    Senior Member
    Join Date
    Aug 2011
    Location
    Cranbourne, Victoria, Australia, Australia
    Posts
    168
    Pm'd you Jimmy.

  5. #5
    Mal Dimal's Avatar
    Join Date
    Oct 2004
    Location
    Warwick, QLD
    Posts
    16,978
    Measuring the Bypass Volume is really nothing better than an indicator, you know. Pretty rough...

    You'd have to allow an error margin of +/- 1.25Bar for a nominal bypass volume. Still far better to use a decent pressure gauge/needle valve setup (or similar). I'd take up the offer above or contact Greg Pullman to use his rental hardware.

    Mal.

  6. #6
    Senior Member
    Join Date
    Aug 2011
    Location
    Cranbourne, Victoria, Australia, Australia
    Posts
    168
    Thanks Mal. Advice has been taken.

  7. #7
    Not a Shoe Jimmytheboot's Avatar
    Join Date
    Jan 2009
    Location
    Melbourne
    Posts
    246
    Would you believe the only piece I needed to put this monstrosity together from parts I had already was a 1/4" nipple?



    snooooze likes this.

  8. #8
    Senior Member
    Join Date
    Mar 2012
    Posts
    1,275
    Arrrghhh ! ..Frankengauge gage !

    Are you sure you couldnt fit a temp probe in there somewhere ?

  9. #9
    Not a Shoe Jimmytheboot's Avatar
    Join Date
    Jan 2009
    Location
    Melbourne
    Posts
    246
    I think with pressure taken care of temperature can be tuned reasonably easily by taste... i.e. I dont have a temp probe

  10. #10
    Senior Member
    Join Date
    Apr 2012
    Posts
    319
    Why do you have a valve on there? Any reason or just needed those fittings to complete the job?

    I'll take a photo of mine which I made a few days ago.

  11. #11
    Senior Member
    Join Date
    Apr 2012
    Posts
    319
    I just went over to Reece plumbing supplies and brought my group handle and gauge. $4.70 later I had a fairly handy tool
    Attached Images Attached Images

  12. #12
    Not a Shoe Jimmytheboot's Avatar
    Join Date
    Jan 2009
    Location
    Melbourne
    Posts
    246
    Quote Originally Posted by brendogs View Post
    Why do you have a valve on there? Any reason or just needed those fittings to complete the job?

    I'll take a photo of mine which I made a few days ago.
    There will be a small difference between the pressure measured with flow and without flow, restrictions/bends in the path between the opv/bypass and the group will cause pressure drops only when theres flow past them

    Nice work, but you got the same gauge at reece for under $4.7? evilbay got me again

  13. #13
    Senior Member
    Join Date
    Apr 2012
    Posts
    319
    Nah I got the gauge off evilbay also.



Similar Threads

  1. BZ40 - group head pressure not stable when adding water pressure limiter
    By pup26 in forum Brewing Equipment - Extreme Machines ($3000+)
    Replies: 4
    Last Post: 19th March 2012, 08:24 PM
  2. Em6910 - No pressure to group head
    By KiwiFrase in forum Brewing Equipment - Midrange ($500-$1500)
    Replies: 2
    Last Post: 7th March 2011, 08:50 AM
  3. Pressure measuring portafilter
    By Sparky in forum Brewing Equipment (non-machine specific)
    Replies: 5
    Last Post: 23rd September 2005, 04:48 PM

Tags for this Thread

Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
  •