Thread: ECM Giotto - tripping power board

  1. #1
    DRG
    DRG is offline
    Junior Member
    Join Date
    Nov 2012
    Posts
    2

    ECM Giotto - tripping power board

    Gene Cafe Coffee Roaster $850 - Free Beans Free Freight
    I have an ECM Giotto that does on average probably 3-4 cups per day. My machine has started to intermittently trip the power board it is connected to. (HPM 10amp normal household power board with overload protection) I had a quick look inside the machine and it all looks clean and dry. (I tried to book the machine in to my preferred site sponsor -Talk Coffee - but they are full until April - they have however suggested the culprit may be the boiler element and/or the control board.)

    Ran the multimeter over the element - continuity ok and resistance circa 44.9 ohms. No idea of how to check any functions on the control board.

    Two questions arise:

    1. any ideas on what else a "non tech" ie myself can check to keep my machine going until booked in for service?
    2. as the issue is intermittent and manifests itself by tripping a resettable power board - any great issues with running the machine over easter?

    cheers


  2. #2
    Senior Member
    Join Date
    Dec 2009
    Location
    SYD
    Posts
    590
    Maybe plug it in direct to a socket and see if this trips the circuit?

    That would help isolate the fault, as it could conceivably be the powerboard.

  3. #3
    TC
    TC is offline
    .
    Join Date
    Oct 2004
    Location
    Melbourne
    Posts
    14,665
    Hello DRG,

    Most likely element or element relay on the control board.

    If it fires up and then fails relatively quickly, the element may be on the way out. If it tends to fail when hot, I'd be looking at the control board.

    We have closed service prior to Easter so that clients with machines being serviced can have an operating machine for Easter. We can probably have you operational (i.e squeeze in a repair) but service would have to wait until April.

    Give me a buzz if you still have issues.

    Chris

  4. #4
    Senior Member
    Join Date
    Dec 2006
    Location
    Perth WA
    Posts
    572
    Definitely test the unit plugged straight into a house hold GPO. I have had trouble with a power board with a faulty overload cut off.
    sprezzatura likes this.

  5. #5
    Senior Member sprezzatura's Avatar
    Join Date
    Dec 2013
    Location
    Toogoom, QLD
    Posts
    931
    Concur: go to a healthy power point. See if it trips your residential RCD.

  6. #6
    DRG
    DRG is offline
    Junior Member
    Join Date
    Nov 2012
    Posts
    2
    Firstly - thanks Chris from Talking Coffee - I will give you a call.


    Quote Originally Posted by sprezzatura View Post
    Concur: go to a healthy power point. See if it trips your residential RCD.
    Thanks also to Herzog, dumiya and sprezzatura - I will try plugging directly into the wall socket (not that optimistic as I had already changed the power board and it tripped the new one as well, albeit not immediately)

  7. #7
    TC
    TC is offline
    .
    Join Date
    Oct 2004
    Location
    Melbourne
    Posts
    14,665
    Quote Originally Posted by DRG View Post
    Firstly - thanks Chris from Talking Coffee
    Just Talk Coffee will be fine.

    Not Talking Coffee, not "what was your website again?", not Coffee Talk, not "who are you?...

    Regardless, glad to help!
    Last edited by TC; 22nd March 2016 at 03:58 PM.
    Dimal likes this.

  8. #8
    Senior Member Magic_Matt's Avatar
    Join Date
    Sep 2007
    Location
    Northlandia
    Posts
    1,363
    Chalk Toffee?