Thread: OPV adjustment on Expobar Office Control

  1. #1
    Senior Member
    Join Date
    Aug 2006
    Posts
    119

    OPV adjustment on Expobar Office Control

    Gene Cafe Coffee Roaster $850 - Free Beans Free Freight
    How difficult is it to adjust the OPV on the Office Control?
    I adjusted my minore and its fairly straight forward. At the moment she is in for repairs and I have a Control on loan that is running at 13 bar :o
    Being a loaner I dont want to mess with it too much but would like to get the brew pressure down if easily possible.

    Regards
    Gavin

  2. #2
    TC
    TC is offline
    .
    Join Date
    Oct 2004
    Location
    Melbourne
    Posts
    14,665

    Re: OPV adjustment on Expobar Office Control

    Quote Originally Posted by Fulcrum link=1185401386/0#0 date=1185401386
    How difficult is it to adjust the OPV on the Office Control?
    I adjusted my minore and its fairly straight forward. At the moment she is in for repairs and I have a Control on loan that is running at 13 bar :o
    Being a loaner I dont want to mess with it too much but would like to get the brew pressure down if easily possible.

    Regards
    Gavin
    Hi Gavin, Its in the same place, you just cant get to it ::)...

    Last time I did one, it took almost an hour to gain access to it....If its on loan, Id suggest dont bother and just hope that yours comes back soon...What happened to the Minore?

    Chris

  3. #3
    Senior Member
    Join Date
    Dec 2005
    Posts
    124

    Re: OPV adjustment on Expobar Office Control

    Fulcrum,

    2 questions:
    1) how did you test the preassure on the minore...i have a minore but dont have a preassure reader, so just wondering if there is another way
    2) how did you adjust the preassure on the minore? was it by drilling the hole behind the driptray?

    I havent really tested the minore, but have a feeling it may be a touch high!

  4. #4
    TC
    TC is offline
    .
    Join Date
    Oct 2004
    Location
    Melbourne
    Posts
    14,665

    Re: OPV adjustment on Expobar Office Control

    This needs to be done with a p/f pressure gauge.

    Boiler pressure gauges dont take a measurement at the group. I have seen machine gauges read up to 1.5 over actual- so a 10.5 bar displayed may actually be the desired 9 bar....

  5. #5
    Senior Member
    Join Date
    Aug 2006
    Posts
    119

    Re: OPV adjustment on Expobar Office Control

    Krusty: I have a pf with a pressure guage to test the brew pressure. The opv is adjusted with a screwdriver; just take the back cover off and you can see the opv just behind the hot water side.
    There is another way where you put a blind filter in and measure the water coming out of the overflow...too complicated for me.
    2MCM: THe temp display doesnt work and the front boiler is not heating up so I suspect the controller is dead. And of course this happened just 2 weeks out of warranty >:(

    Gavin

  6. #6
    TC
    TC is offline
    .
    Join Date
    Oct 2004
    Location
    Melbourne
    Posts
    14,665

    Re: OPV adjustment on Expobar Office Control

    Quote Originally Posted by Fulcrum link=1185401386/0#4 date=1185425191
    Krusty: I have a pf with a pressure guage to test the brew pressure. The opv is adjusted with a screwdriver; just take the back cover off and you *can see the opv just behind the hot water side.
    There is another way where you put a blind filter in and measure the water coming out of the overflow...too complicated for me.
    2MCM: THe temp display doesnt work and the front boiler is not heating up so I suspect the controller is dead. And of course this happened just 2 weeks out of warranty * *>:(

    Gavin
    Gavin- This is a known issue with early build Minore/Minore II....The fix is new Aussie board and contoller. Id make a HEAP of noise and do my utmost to have it covered. The vendor MUST refer it back to Expobar. Their support has been excellent on this matter. Labour is circa $100-150 and $$$ in parts...Warranty would be good ;-)

    2mcm

  7. #7
    Senior Member
    Join Date
    Aug 2006
    Posts
    119

    Re: OPV adjustment on Expobar Office Control

    2MCM

    Yup, that was my plan: see what the fault is and then push for a warranty repair.

    Gavin

  8. #8
    .
    Join Date
    Aug 2004
    Posts
    2,312

    Re: OPV adjustment on Expobar Office Control

    With regard to original question...leave it alone.

    It doth not belong to you. I will wager that the coffee it is making is just fine anyway, and you probably wouldnt have thought anything was out of the ordinary if you hadnt put a gauge up to it.


    Regardz,
    FC.

  9. #9
    Senior Member
    Join Date
    Jul 2006
    Posts
    434

    Re: OPV adjustment on Expobar Office Control

    "...you probably wouldnt have thought anything was out of the ordinary if you hadnt put a gauge up to it."

    Good point. My Isomac Mondiale has been running at 12 bar indicated on its
    pressure gauge since coming back from a minor repair a few months ago.
    I decided not to worry about it, as its producing excellent coffee. But I do
    wonder sometimes what difference it makes ....

  10. #10
    Sleep is overrated Thundergod's Avatar
    Join Date
    Jul 2006
    Location
    Sydney
    Posts
    10,496

    Re: OPV adjustment on Expobar Office Control

    Quote Originally Posted by Fulcrum link=1185401386/0#6 date=1185428979
    2MCM

    Yup, that was my plan: see what the fault is and then push for a warranty repair.

    Gavin
    If you are in NSW youd have a good chance.
    When things in that price range break down just outside warranty period Fair Trading and the ACC take your side.

    Its an "Implied Warranty".
    http://www.fairtrading.nsw.gov.au/shopping/refundsrepairs/warranties.html

    See also the "Examples" in the ACCC brochure.
    Click here for ACCC brochure.

  11. #11
    Senior Member
    Join Date
    Jul 2006
    Posts
    434

    Re: OPV adjustment on Expobar Office Control


    " Its an "Implied Warranty". "

    I think the ACCC provisions would cover it nationwide, under
    the notion of fitness for purpose and expectation of servicable
    life.

    I have a smartphone with notionally a one year warranty. The screen just
    died after two years. I argued with them on the above basis and
    promptly received a replacement, after they agreed with me that it
    was reasonable to expect the device to work for at least three years.

  12. #12
    Senior Member
    Join Date
    Aug 2006
    Posts
    119

    Re: OPV adjustment on Expobar Office Control

    FC: You just lost a bet, what do I win ;)

  13. #13
    Senior Member
    Join Date
    Aug 2006
    Posts
    119

    Re: OPV adjustment on Expobar Office Control

    So there I was cleaning the loaner before I return it and what do I spot but the OPV, easily accessible once the water jug has been removed.
    As FC has said not my machine so I wouldnt go changing anything but good to know for other owners or potential owners of the Control.





Similar Threads

  1. !!SOLD!!: Expobar Office Control
    By barnsey in forum SOLD
    Replies: 14
    Last Post: 3rd August 2011, 02:20 PM
  2. !!SOLD!!: Expobar Office Control (FA)
    By mattchewhart in forum SOLD
    Replies: 7
    Last Post: 2nd July 2010, 06:04 PM
  3. Expobar Office Control Semi vs Expobar Office Leva
    By bluedevilfish in forum Brewing Equipment (non-machine specific)
    Replies: 10
    Last Post: 15th December 2006, 12:58 AM

Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
  •