Thread: Giotto Premium Plus: Pressure gauge sticks on .15 bar when cold

  1. #1
    Junior Member
    Join Date
    Oct 2013
    Posts
    13

    Giotto Premium Plus: Pressure gauge sticks on .15 bar when cold

    Gene Cafe Coffee Roaster $850 - Free Beans Free Freight
    Not sure when this started happening but I recently noticed the boiler pressure gauge no longer returns to zero when cold. It bottoms out around .15 bar. It otherwise appears to work as expected, though I have no idea whether it's reflecting the actual boiler pressure.

    Any ideas what might be causing this?

    Thanks

  2. #2
    Senior Member
    Join Date
    Jul 2017
    Posts
    134
    Quote Originally Posted by Seaperson View Post
    Not sure when this started happening but I recently noticed the boiler pressure gauge no longer returns to zero when cold. It bottoms out around .15 bar. It otherwise appears to work as expected, though I have no idea whether it's reflecting the actual boiler pressure.

    Any ideas what might be causing this?

    Thanks
    It's probably a small rock of limescale blocking the capillary tube to the gauge. Can be a sign that descale/service is required
    Dimal likes this.

  3. #3
    Junior Member
    Join Date
    Oct 2013
    Posts
    13
    Quote Originally Posted by Caffeinator View Post
    It's probably a small rock of limescale blocking the capillary tube to the gauge. Can be a sign that descale/service is required
    Makes sense. Shouldn't need descaling though, did that recently. Perhaps I dislodge a chunk of scale in that process.
    Dimal likes this.