Results 1 to 11 of 11
Like Tree3Likes
  • 2 Post By kofekitt
  • 1 Post By level3ninja

Thread: Elektra Semi-autiomatica SXC over current issue

  1. #1
    Junior Member
    Join Date
    Oct 2018
    Posts
    5

    Elektra Semi-autiomatica SXC over current issue

    Gene Cafe Coffee Roaster $850 - Free Beans Free Freight
    Good Morning,

    I am having an issue with my Elektra Semiautomatica SXC blowing my home circuit when its switched on, Has anyone has this issue at all? or know where I can get my hands on a wiring diagram / schematic so that i can diagnose the fault? I have had a quick look over the machine, nothing appears to be shorting out to ground, the element is around 60 ohms.

    Cheers

    Brad

  2. #2

  3. #3
    Junior Member
    Join Date
    Oct 2018
    Posts
    5
    Thanks JMcCee, that helps for an exploded view of parts, but i'm after an actual wiring / circuit diagram to troubleshoot the problem

    Cheers

    Brad

  4. #4
    Senior Member
    Join Date
    Jul 2009
    Posts
    249
    Have you tested the element leakage to earth? Even though it shows 60 ohms resistance, it can still be leaking to earth and tripping. Unfortunately the most common fault with these, and a pain to change that element!!
    saeco_user and bcoutts like this.

  5. #5
    Junior Member
    Join Date
    Oct 2018
    Posts
    5
    Quote Originally Posted by kofekitt View Post
    Have you tested the element leakage to earth? Even though it shows 60 ohms resistance, it can still be leaking to earth and tripping. Unfortunately the most common fault with these, and a pain to change that element!!
    Ok thanks kofekitt, no I have not checked that, also do you happen to know the resistance of a known good element?

    Thanks

  6. #6
    Senior Member
    Join Date
    Jul 2009
    Posts
    249
    Depends on the supply voltage and element style as there are two elements, but 60 ohms at 240v sounds about right . For earth leaks, one probe on either element terminal, and the other probe to metal body of machine or known earth connection. Should be higher than 10 mega ohms , sometimes they only fail when hot, but will get progressively worse . Be careful with electricity and make sure machine is un-plugged

  7. #7
    Senior Member level3ninja's Avatar
    Join Date
    Nov 2013
    Location
    Sydney
    Posts
    1,274
    Really needs to be tested with an insulation resistance tester and not just a multimeter on resistance to be certain. Disconnect the element completely and test between the electrical connection point and the metal case of the element at 250V and then 500V.

    Also when you say "blowing the circuit", is it tripping an RCD, or circuit breaker, or combination RCD/MCB, or fuse...
    Dimal likes this.

  8. #8
    Senior Member deegee's Avatar
    Join Date
    Sep 2012
    Location
    Brisbane Southside
    Posts
    344
    Quote Originally Posted by bcoutts View Post
    Good Morning, I am having an issue with my Elektra Semiautomatica SXC blowing my home circuit when its switched on, Has anyone has this issue at all? or know where I can get my hands on a wiring diagram / schematic so that i can diagnose the fault? I have had a quick look over the machine, nothing appears to be shorting out to ground, the element is around 60 ohms. Cheers Brad
    Yes, I had this exact problem a few months ago with my Semiautomatica.

    At my house, which doesn't have RCD's it was working OK, but when I tried to use it at a friend's home, it tripped the breaker as soon as it was turned on.
    Testing with a multi-meter showed that there was leakage between the element and the boiler. When the element was removed and completely dried out, it tested OK, but after soaking for a few hours in water it tested low resistance again. It didn't look too badly corroded, but there must have been a pinhole or a fine crack in the outer casing allowing water to seep in.