    replacing Giotto controller with a DIY controller

    Gene Cafe Coffee Roaster $850 - Free Beans Free Freight
    Hi all,

    it's been a while since I've been here. I've been plodding along fairly happy with my FZRR drum roaster; Gino Rossi grinder & ECM Giotto (2007) until the Giotto stopped heating a couple of weeks ago

    After some diagnosis I found that the water sensors, pressure sensor, element and pump are all ok, but the relay on the controller is 0xDEAD!

    I see some drop-in replacement controllers around $300 (I didn't think they made this one anymore so they must be an aftermarket compatible thing) but what I really want to do is replace it with my own design for a bit of fun and learning.

    I'm comfortable with the programming & purchasing side of things, but at this stage I'm not 100% sure how to use the existing water sensors. Has anyone tried this themselves? I may have to do some measurements.

    I'm not going to do any PID controlled solid-state relays or anything flash - maybe later. I'm just going to start with a like-for-like replacement. An Arduino with some extra bits n pieces would be sufficient. As far as I can tell, this is what it comes down to:

    Inputs:
    1. tank water sensor (need to put some voltage on a wire and detect an open circuit to ground to see if there is water)
    2. boiler water sensor (same as above)
    3. boiler pressure switch (just uses a microswitch)
    4. lever switch


    Outputs:
    1. Pump (looks like a 240V relay but not sure)
    2. Element (240V relay)
    3. maybe some sort of water valve to direct pump water to the boiler vs group - not sure yet


    There's also a bit of corrosion around some of the copper fittings, so I may end up taking the boiler out but we'll see.

    Well, what do you think? Anyone done this before who would care to comment?

    In the meantime, enjoy your nice coffee, cause I'm drinking from a moka pot!

  2. #2
    Senior Member Lyrebird's Avatar
    Join Date
    Jun 2018
    Posts
    513
    Yeah, I've done it, they're pretty simple. My design is all analogue since I don't do digital, but the principles are the same.

    The water sensors are both run on comparators: You need a high value resistor between Vcc and the probe, then use the comparator with the voltage at this junction and a reference (eg Vcc/2) as its inputs.

    You do need a third output for the water solenoid.

    You do want to put an SSR in for the element, much better than an electromechanical relay. The pump and solenoid can be electromechanical relays, these are fairy low power. I use Omron G2R1A, available from RS for about $6 each, they mount on the panel and have standard 6mm spade connectors so they are very easy to use.

    Power requirements are another thing: it's easiest to run the relays etc on say 12V but you then need a lower voltage for Vdd for the uC (3.3V?). I find the easiest thing to do is to use a 12V regulated plugpack which I hack to take wired input instead of the 240V prongs. This can be made waterproof and tucked into the body of the machine, then you can just put a regulator on the board to provide Vdd.
    Last edited by Lyrebird; 30th June 2019 at 06:36 PM.
    Dimal, iaindb and Jackster like this.

  3. #3
    Senior Member level3ninja's Avatar
    Join Date
    Nov 2013
    Location
    Sydney
    Posts
    1,461
    If you wanted a less exciting project you could always just replace the relay...

    If you are getting a SSR make sure to get one rated at twice the current it's switching.

  4. #4
    Senior Member Lyrebird's Avatar
    Join Date
    Jun 2018
    Posts
    513
    The element pulls around 5A. The common SSRs are 25A or 40A, so he's unlikely to get into trouble there.

  5. #5
    Senior Member level3ninja's Avatar
    Join Date
    Nov 2013
    Location
    Sydney
    Posts
    1,461
    Quote Originally Posted by Lyrebird View Post
    The element pulls around 5A. The common SSRs are 25A or 40A, so he's unlikely to get into trouble there.
    Ok that's good, working in industry I'm always switching higher loads and upsizing to suit.

  6. #6
    Senior Member Lyrebird's Avatar
    Join Date
    Jun 2018
    Posts
    513
    Yeah the usual problem is that most things have a fairly positive temperature coefficient of resistance* so the current draw when cold is a lot higher than when hot: I use old transmitting triodes in one of my amps and they have a hot / cold ratio of about 10: 1, so I need current limiters on the inputs (also helps extend the life of these things which are now pretty well unobtainium).

    Old fashioned tungsten light bulbs were even worse, up to 15:1 which is why they just about always blew at turn on.

  7. #7
    Senior Member
    Join Date
    Dec 2008
    Posts
    1,048
    Nice ideas, thanks.

    level3ninja where's the fun in just replacing the relay? Plus my soldering sucks and I'd have no excuse to play around!

    Yes a SSR would be good, but not yet as I'm not changing out the pressure switch just yet. Maybe later - I'll get it working first. Unless they're cheap and I can use it as a slow relay for now.

    You can get 3.3V triggered (or low triggered) relays and shields for the arduino, but I haven't seen any over 5A yet. I'll keep looking.

    thanks for the replies!

  8. #8
    Coffee Nut fg1972's Avatar
    Join Date
    Jan 2012
    Location
    Melbourne
    Posts
    451
    Quote Originally Posted by iaindb View Post
    Nice ideas, thanks.

    level3ninja where's the fun in just replacing the relay? Plus my soldering sucks and I'd have no excuse to play around!

    Yes a SSR would be good, but not yet as I'm not changing out the pressure switch just yet. Maybe later - I'll get it working first. Unless they're cheap and I can use it as a slow relay for now.

    You can get 3.3V triggered (or low triggered) relays and shields for the arduino, but I haven't seen any over 5A yet. I'll keep looking.

    thanks for the replies!
    You could always get the small low volt coli arduino relay to control a larger relay.

  9. #9
    Senior Member
    Join Date
    Dec 2008
    Posts
    1,048
    Quote Originally Posted by fg1972 View Post
    You could always get the small low volt coli arduino relay to control a larger relay.
    I've never done a daisy-chained relay before - anyone done that and have advice to offer?

    The existing relay is a jqx-115f - 16A.

    It looks like some SSRs can be triggered at 3V and can switch large loads in smaller sizes, so maybe I'll use one of those anyway. I can only find this 40A model: https://www.sparkfun.com/products/13015. Lyrebird were you saying the cold current draw affects the relay or the element? Do I need to worry about soft startup or leakage current?

    What about a MOSFET relay?

    So many questions!
    Last edited by iaindb; 8th July 2019 at 10:03 PM. Reason: spelling

  10. #10
    Senior Member
    Join Date
    Dec 2008
    Posts
    1,048
    For those following, I've ordered a Wemos D1 mini, as it has plenty of DIO, one analog input I can use later for the PID, and includes WiFi on-chip. It has relay shields, but I'll need a separate SSR for the element - probably a Fotek 25A or something like that - it will need to trigger off 3.3V. Just waiting on APost to deliver the parts!

  11. #11
    Senior Member Jackster's Avatar
    Join Date
    Nov 2017
    Location
    Maddington, Perth. Wa
    Posts
    976
    I have a similar issue, but my pressurestat runs ac to it. My SSR are DC triggered, so waiting for some ac-ac SSR to arrive.

    But watching this to see where you end up...
    Dimal likes this.

  12. #12
    Senior Member
    Join Date
    Dec 2008
    Posts
    1,048
    Quote Originally Posted by Jackster View Post
    I have a similar issue, but my pressurestat runs ac to it. My SSR are DC triggered, so waiting for some ac-ac SSR to arrive.

    But watching this to see where you end up...
    You could probably rewire it, as I think this ac pressurestat was redesigned to use the same pressurestat as a dc input. From what I can gather the AC eventually burns out the pressurestat switch.

    You can see the two different wiring options in this PDF: https://www.home-barista.com/downloa...E-13.03.09.pdf

  13. #13
    Mal Dimal's Avatar
    Join Date
    Oct 2004
    Location
    Warwick, QLD
    Posts
    16,770
    Quote Originally Posted by iaindb View Post
    From what I can gather the AC eventually burns out the pressurestat switch.
    That's more of a DC issue Iain.
    Not so much with AC since at halfway through every cycle, the voltage is Zero....

    Mal.

  14. #14
    Mal Dimal's Avatar
    Join Date
    Oct 2004
    Location
    Warwick, QLD
    Posts
    16,770
    Quote Originally Posted by iaindb View Post
    You can see the two different wiring options in this PDF: https://www.home-barista.com/downloa...E-13.03.09.pdf
    Or, maybe this one...
    https://coffeesnobs.com.au/attachmen...a-part2of2.pdf

    Mal.
    iaindb likes this.

  15. #15
    Senior Member
    Join Date
    Dec 2008
    Posts
    1,048
    Thanks Mal, I happily defer to your expertise as I’ve seen inside a grand total of 1 of these machines!

    So are you saying the DC pressurestat is a problem?

  16. #16
    Senior Member Jackster's Avatar
    Join Date
    Nov 2017
    Location
    Maddington, Perth. Wa
    Posts
    976
    I been browsing the wemos mini, will you run the screen and SD card as well?

  17. #17
    Senior Member
    Join Date
    Dec 2008
    Posts
    1,048
    I’ve ordered the screen to play with, but it probably won’t go on the final version as I’m mounting the whole lot inside the machine...

  18. #18
    Mal Dimal's Avatar
    Join Date
    Oct 2004
    Location
    Warwick, QLD
    Posts
    16,770
    Quote Originally Posted by iaindb View Post
    So are you saying the DC pressurestat is a problem?
    Given identical load and voltage, DC Contacts need to be a bit beefier and have a means of quenching (usually magnetic) the arc resulting when the contacts are opened while loaded. This scenario doesn't apply when being used for an AC load.

    That's why it is always important to properly specify relays/contactors for the type of load to which they will be subjected.

    Mal.

  19. #19
    Senior Member
    Join Date
    Dec 2008
    Posts
    1,048
    Quote Originally Posted by Dimal View Post
    Given identical load and voltage, DC Contacts need to be a bit beefier
    Yes, when comparing identical load and voltage, but I'm referring to the GPP wiring which is either a) low voltage (5V/12V?) DC negligible load on the pressurestat; or b) 240V AC carrying 1500W!

    Buuuuut I'm trying to get some clarity on the Giotto wiring "versions", as I've seen wiring diagrams saying the in-line pressurestat is the latest, but the one posted above says the pressurestat wired separately to the control box is the latest...

    thanks!

  20. #20
    Mal Dimal's Avatar
    Join Date
    Oct 2004
    Location
    Warwick, QLD
    Posts
    16,770
    Quote Originally Posted by iaindb View Post
    Yes, when comparing identical load and voltage, but I'm referring to the GPP wiring which is either a) low voltage (5V/12V?) DC negligible load on the pressurestat; or b) 240V AC carrying 1500W!
    The P/stat contacts will be fine and designed to handle the miniscule load placed on them (a relay coil).
    The relay main contacts are well able to handle the load required of them.

    Mal.

  21. #21
    Senior Member
    Join Date
    Dec 2008
    Posts
    1,048
    Quote Originally Posted by Dimal View Post
    The P/stat contacts will be fine and designed to handle the miniscule load placed on them (a relay coil).
    The relay main contacts are well able to handle the load required of them.
    We're talking passed each other... Perhaps I'm not explaining myself properly. But nevermind, my parts have arrived so I'll wire it as it is currently.

  22. #22
    Senior Member
    Join Date
    Dec 2008
    Posts
    1,048
    Le parts have arrived. They're quite tiny!

    IMG_3597.jpg

  23. #23
    Senior Member Barry O'Speedwagon's Avatar
    Join Date
    Dec 2011
    Location
    PRL
    Posts
    2,613
    Quote Originally Posted by iaindb View Post
    Le parts have arrived. They're quite tiny!

    IMG_3597.jpg
    Les parts
    iaindb likes this.