    PIDing a heat exchanger machine

    Gene Cafe Coffee Roaster $850 - Free Beans Free Freight
    Hi there,

    Just a question for the skilled and knowledgeable. I am tinkering with PID'ing my heat exchanger machine (Astoria CKX) to get more thermostability during the extraction. Since the heat exchanger type, is it a waste of time?

    If it has been done before, is there any guides out there.

    Regards,
    Andy

  2. #2
    Not a Shoe Jimmytheboot's Avatar
    Join Date
    Jan 2009
    Location
    Melbourne
    Posts
    246
    Its a waste of time for that reason, a pressure swing for example between 1 and 1.2 bar (gauge pressure) only equates to around 4deg temperature change in the boiler, the change in the brew water will be a little less and then buffered by the thermal mass of group

    Its been done before and can be done the same way as piding a single boiler, bezzera even makes the BZ07 with a pid

    To get a stable brew temperature from HX machine requires a combination of 1. boiler pressure + good HX design for sufficient brew temp through to the end of the shot, and 2. idle group temp control (thermosyphon restrictors) for correct temp at the start of the shot

  3. #3
    Member
    Join Date
    Feb 2010
    Location
    Melbourne
    Posts
    81
    Yeah. Just wanted to confirm my thoughts and what I was reading in on Should I PID my Heat Exchanger? - Knockbox • Home-Barista.com

    Their application is more on shot recovery than brew stability?

  4. #4
    Not a Shoe Jimmytheboot's Avatar
    Join Date
    Jan 2009
    Location
    Melbourne
    Posts
    246
    How much pressure swing do you have?

    The machine in that thread is different to yours with the HX section of the boiler connected directly to the grouphead, it would overheat

    There are reasons to pid, no more clang/ping from the pressurestat for example

  5. #5
    Member
    Join Date
    Feb 2010
    Location
    Melbourne
    Posts
    81
    Thank Jim.

    I think the CKX tends to run hot while idling thus requires a flush before use. I am going to attach a probe to the grouphead to detect the change in temp during flush. As for boiler pressure and design, I am not too sure about the CKX design and adjustments.

    No boiler pressure reading available... only steaming pressure gauge...

  6. #6
    Senior Member
    Join Date
    Mar 2012
    Posts
    1,275
    Quote Originally Posted by coffeeboy83 View Post
    No boiler pressure reading available... only steaming pressure gauge...
    Errr ? ... Steaming pressure IS boiler pressure !

  7. #7
    Member
    Join Date
    Feb 2010
    Location
    Melbourne
    Posts
    81
    Ah... yes. indeed.... opps

    is that adjustment dependent on the pressurestat? (how do you adjust that?)

  8. #8
    Site Sponsor coffee_machinist's Avatar
    Join Date
    Jun 2011
    Posts
    683
    The CKX group might be a candidate for an active heating conversion, I've just made one for a commercial Bezzera. Basically a small brass block with built-in PID controlled heaters gets bolted on between the group and solenoid, providing precise temperature control of the group. This is complimented by a thermosyphon restrictor to lower the group's initial idle temp. and allow the PID to fine tune it.

    Some domestic Bezzeras have actively heated groups as standard (that's where I got the idea), but they are using thermostat control at present.
    Attached Images Attached Images

  9. #9
    Member
    Join Date
    Feb 2010
    Location
    Melbourne
    Posts
    81
    Hi Coffee machinist, I have been admiring your work. Some questions came to mind,

    1) Why do you think it is a candidate for active heating conversion? Is it because of the availability of room within the machine chassis to install such a device?
    2) The CKX is not a standard E61 grouphead, does it have a thermosyphon restrictor? <--- just read your website
    Answer is NO! CKX does not have a thermosyphon restrictor

    Thanks.

    Andy

  10. #10
    Site Sponsor coffee_machinist's Avatar
    Join Date
    Jun 2011
    Posts
    683
    Hi Andy, thanks.

    To answer your questions,

    1) You need a decent flat surface under the group where the solenoid bolts on, as the heat is transferred to the group via conduction across the brass. The larger the flat surface, the more efficient it is. The bezzera group is up to temperature from cold in a matter of minutes, with 200W heaters.

    2) Correct. The only reason to add a restrictor in this case is to make sure the group isn't running too hot in the first place, as the heater can only, well, heat.

  11. #11
    Not a Shoe Jimmytheboot's Avatar
    Join Date
    Jan 2009
    Location
    Melbourne
    Posts
    246
    Nice idea cm, how many watts?

    Looks like the same config would work on the ckx


  12. #12
    Member
    Join Date
    Feb 2010
    Location
    Melbourne
    Posts
    81
    1) The internals of a CKX has been well documented in this forum thanks to LaceHim and A_M see: http://coffeesnobs.com.au/brewing-eq...project-4.html

    Seem like there is alot of potential room for the heater to go onto?

    2) I assume then the boiler pressure has to be brought down to accommodate this drop in temperature? Does this mean a new pressurestat or adjustment possible with the stock pressurestat?

  13. #13
    Member
    Join Date
    Feb 2010
    Location
    Melbourne
    Posts
    81
    Behmor Brazen - $249 - Free Freight
    Jim... might need your PID kit afterall. Maybe a double PID on the cards?

    1) for the grouphead heating element
    2) for the boiler and disable pressurestat?



Similar Threads

  1. What is a heat exchanger?
    By malliemcg in forum Brewing Equipment (non-machine specific)
    Replies: 10
    Last Post: 3rd December 2010, 08:35 PM
  2. Cooling flush of a (HX) Heat Exchanger Machine
    By Koffee_Kosmo in forum General Coffee Related...
    Replies: 19
    Last Post: 8th November 2008, 06:53 PM
  3. What is a heat exchanger?
    By sugilun in forum Brewing Equipment - Pointy End ($1500-$3000)
    Replies: 3
    Last Post: 25th February 2008, 09:30 AM
  4. Replies: 3
    Last Post: 14th May 2007, 02:25 PM

Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
  •