    Re building an E61 two group machine

    Gene Cafe Coffee Roaster $850 - Free Beans Free Freight
    Hi coffee people
    well my next project is starting to take shape, I'm planing to open a small coffee shop at the end of the year and to this end I have been looking at many different machines but as I have both the resources and the ability I have decide to re build and re skin a machine . I got very lucky and have been given a 2 group E61 leaver machine in very good nick, this will be the base for my new machine. My question is about moving the group heads away from the boiler . My new design will move the group heads about 150mm further away from the boilers thermal couple unit . Does any one know if this would have a adverse affect on the water temp reaching the group heads or are there ways to increase the temperature from the boiler . Any info would be much appreciated .

  2. #2
    Senior Member
    Join Date
    Mar 2012
    Posts
    1,275
    for certain it will make a difference, but how much is difficult to guess.
    Remember the group is heated by the thermosyphon effect from the boiler, so distance, and relative height will both play a part as well as tubing size, routing and any restrictor /regulator valve system that may or may not be installed.
    I suspect you will need to do a bit of testing !

  3. #3
    Junior Member
    Join Date
    Dec 2012
    Location
    Balgownie
    Posts
    23
    Behmor Brazen - $249 - Free Freight
    Quote Originally Posted by blend52 View Post
    for certain it will make a difference, but how much is difficult to guess.
    Remember the group is heated by the thermosyphon effect from the boiler, so distance, and relative height will both play a part as well as tubing size, routing and any restrictor /regulator valve system that may or may not be installed.
    I suspect you will need to do a bit of testing !
    Thanks blend52 I figured that would be the case . I'm looking at maby fitting a secondary boiler with PID for each group head but ill have to see how it behaves. As u say a bit of testing and experimenting



Similar Threads

  1. A few questions for building a new roasting machine
    By brettryan in forum Home Roasting - Tips, Tricks, Ideas
    Replies: 26
    Last Post: 11th October 2012, 09:35 PM
  2. Building my own roaster
    By shsdarwin in forum Home Roasting - Tips, Tricks, Ideas
    Replies: 11
    Last Post: 28th September 2009, 09:06 AM
  3. building a breville 800
    By fauxhenrys in forum Brewing Equipment - Entry level (sub $500)
    Replies: 11
    Last Post: 22nd January 2009, 03:27 PM
  4. Reduced H2O flow on one group of a 2 group machine
    By Paolo in forum Brewing Equipment (non-machine specific)
    Replies: 4
    Last Post: 14th December 2006, 08:53 PM

Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
  •